Effect of pulsed electromagnetic field therapy in patients undergoing total knee arthroplasty: a randomised controlled trial

Paolo Adravanti, Stefano Nicoletti, Stefania Setti, Aldo Ampollini, Laura de Girolamo

PAPERmanualInt Orthop2014randomized trialEffect: benefitEvidence: Low

Abstract

Purpose: It has been reported that even one year after total knee arthroplasty (TKA), a relevant percentage of patients does not attain complete recovery and indicate unfavourable long-term pain outcome. We compared the clinical outcome of 33 patients undergoing TKA randomly assigned to the control or the pulsed electromagnetic field group (I-ONE therapy). Methods: I-ONE therapy was administered postoperatively four hours per day for 60 days. Patients were assessed before surgery and then at one, two and six months postoperatively using international scores. Results: One month after TKA, pain, knee swelling and functional score were significantly better in the treated compared with the control group. Pain was still significantly lower in the treated group at the six month follow-up. Three years after surgery, severe pain and occasional walking limitations were reported in a significantly lower number of patients in the treated group. Conclusions: Advantages deriving from early control of joint inflammation may explain the maintenance of results at follow-up. I-ONE therapy should be considered an effective completion of the TKA procedure.

AI evidence extraction

At a glance
Study type
randomized trial
Effect direction
benefit
Population
Patients undergoing total knee arthroplasty (TKA)
Sample size
33
Exposure
pulsed electromagnetic field therapy (I-ONE therapy) · 4 hours/day for 60 days postoperatively
Evidence strength
Low
Confidence: 74% · Peer-reviewed: yes

Main findings

At 1 month after TKA, pain, knee swelling, and functional score were significantly better in the pulsed electromagnetic field (I-ONE) group than in controls. Pain remained significantly lower at 6 months, and at 3 years severe pain and occasional walking limitations were reported by a significantly lower number of treated patients.

Outcomes measured

  • pain
  • knee swelling
  • functional score
  • severe pain at 3 years
  • occasional walking limitations at 3 years

Limitations

  • Small sample size (n=33)
  • EMF exposure parameters (e.g.
  • frequency
  • intensity) not reported in abstract
  • Details of randomization
  • blinding
  • and control condition not described in abstract
View raw extracted JSON
{
  "study_type": "randomized_trial",
  "exposure": {
    "band": null,
    "source": "pulsed electromagnetic field therapy (I-ONE therapy)",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": "4 hours/day for 60 days postoperatively"
  },
  "population": "Patients undergoing total knee arthroplasty (TKA)",
  "sample_size": 33,
  "outcomes": [
    "pain",
    "knee swelling",
    "functional score",
    "severe pain at 3 years",
    "occasional walking limitations at 3 years"
  ],
  "main_findings": "At 1 month after TKA, pain, knee swelling, and functional score were significantly better in the pulsed electromagnetic field (I-ONE) group than in controls. Pain remained significantly lower at 6 months, and at 3 years severe pain and occasional walking limitations were reported by a significantly lower number of treated patients.",
  "effect_direction": "benefit",
  "limitations": [
    "Small sample size (n=33)",
    "EMF exposure parameters (e.g., frequency, intensity) not reported in abstract",
    "Details of randomization, blinding, and control condition not described in abstract"
  ],
  "evidence_strength": "low",
  "confidence": 0.74,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "pulsed electromagnetic field",
    "PEMF",
    "I-ONE therapy",
    "total knee arthroplasty",
    "postoperative pain",
    "knee swelling",
    "functional outcome",
    "randomised controlled trial"
  ],
  "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 2755

Effect of pulsed electromagnetic field therapy in patients undergoing total knee arthroplasty: a randomised controlled trial · Non-native EMF