Share

A Prospective Comparative Study of Pulsed High-Intensity Laser Therapy and Pulsed Electromagnetic Field on Chronic Nonspecific Low Back Pain.

Walid Kamal Abdelbasset, Gopal Nambi, Shereen H Elsayed, Gaber S Soliman, Ahmed A Alessi, Ibrahim N Alsalem, Saeed M Alwadai

PAPERpubmedPhotobiomodulation, photomedicine, and laser surgery2021randomized trialEffect: benefitEvidence: Moderate

Abstract

This study explored the different effects of pulsed high-intensity laser therapy (HILT) versus pulsed electromagnetic field (EMF) in the treatment of chronic nonspecific low back pain (ChNsLBP). Between August and December 2019, 51 ChNsLBP participants with a mean age of 35.2 ± 8.6 years were enrolled in this prospective comparative study. At random, they were divided into three groups, 17 in each; HILT, EMF, and controls. HILT group was recruited for Nd:YAG laser using the following parameters: a wavelength of 1064 nm, fluency of 610-810 mJ, frequency of 10-40 Hz, average power of 10.5 W, and 120 μs short pulse duration in scanning mode. All groups received the treatment twice a week for 8 consecutive weeks. They were assessed for the modified Oswestry disability index (MODI), pain disability index (PDI), visual analog scale (VAS), and lumbar flexion range of motion (flex ROM) before and after 8 weeks of study program. The results showed greater improvement in the HILT group (VAS, PDI, MODI, and lumbar flex ROM, = 0.001) than the EMF group (VAS, = 0.002, PDI, = 0.045, MODI, = 0.002, and lumbar flex ROM, = 0.042), with significant difference between the two groups in favor of the HILT group ( ˂ 0.05). Depending on the results of the study, both HILT and EMF are useful physiotherapy modalities in the treatment of ChNsLBP with HILT exhibiting better outcomes than EMF. Clinical recommendations should be highlighted to instigate the use of HILT in the management of musculoskeletal disorders, distinctively ChNsLBP.

AI evidence extraction

At a glance
Study type
randomized trial
Effect direction
benefit
Population
Participants with chronic nonspecific low back pain (ChNsLBP); mean age 35.2 ± 8.6 years
Sample size
51
Exposure
therapeutic pulsed electromagnetic field · twice a week for 8 consecutive weeks
Evidence strength
Moderate
Confidence: 74% · Peer-reviewed: yes

Main findings

Both pulsed high-intensity laser therapy (HILT) and pulsed electromagnetic field (EMF) groups showed significant pre-post improvements after 8 weeks on pain, disability, and lumbar flexion ROM measures, with greater improvements reported in the HILT group than the EMF group and a significant between-group difference favoring HILT.

Outcomes measured

  • Modified Oswestry Disability Index (MODI)
  • Pain Disability Index (PDI)
  • Visual Analog Scale (VAS)
  • Lumbar flexion range of motion (flex ROM)

Limitations

  • EMF exposure parameters (e.g.
  • field strength
  • frequency) not reported in the abstract
  • Short follow-up limited to immediate post-treatment (8 weeks)
  • Small sample size (17 per group)
View raw extracted JSON
{
  "study_type": "randomized_trial",
  "exposure": {
    "band": null,
    "source": "therapeutic pulsed electromagnetic field",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": "twice a week for 8 consecutive weeks"
  },
  "population": "Participants with chronic nonspecific low back pain (ChNsLBP); mean age 35.2 ± 8.6 years",
  "sample_size": 51,
  "outcomes": [
    "Modified Oswestry Disability Index (MODI)",
    "Pain Disability Index (PDI)",
    "Visual Analog Scale (VAS)",
    "Lumbar flexion range of motion (flex ROM)"
  ],
  "main_findings": "Both pulsed high-intensity laser therapy (HILT) and pulsed electromagnetic field (EMF) groups showed significant pre-post improvements after 8 weeks on pain, disability, and lumbar flexion ROM measures, with greater improvements reported in the HILT group than the EMF group and a significant between-group difference favoring HILT.",
  "effect_direction": "benefit",
  "limitations": [
    "EMF exposure parameters (e.g., field strength, frequency) not reported in the abstract",
    "Short follow-up limited to immediate post-treatment (8 weeks)",
    "Small sample size (17 per group)"
  ],
  "evidence_strength": "moderate",
  "confidence": 0.74,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "pulsed electromagnetic field",
    "PEMF",
    "high-intensity laser therapy",
    "HILT",
    "Nd:YAG",
    "chronic nonspecific low back pain",
    "pain",
    "disability",
    "range of motion",
    "randomized controlled trial",
    "physiotherapy"
  ],
  "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 5703

A Prospective Comparative Study of Pulsed High-Intensity Laser Therapy and Pulsed Electromagnetic Field on Chronic Nonspecific Low Back Pain. · Non-native EMF