[Modulating effect of weak combined magnetic fields on duration of mealworm beetle Tenebrio molitor metamorphosis stage].
Abstract
It is shown that an exposure of pupae of the mealworm beetle Tenebrio molitor to the combined static (42 μT) and very weak alternating (250 nT) magnetic fields exerts different influence, depending on the frequency of the alternating magnetic field, on duration of metamorphosis processes in these insects. For instance, an exposure of pupae to weak combined magnetic fields, adjusted to the frequency of ion cyclotron resonance for glutaminic acid (4,4 Hz), stimulates metamorphosis process--a transitional stage from pupae to imago lasts shorter. An inhibiting effect was observed when adjusted to the frequency of ion cyclotron resonance for Ca2 (32,2 Hz). At some frequencies this effect is not seen. For instance, an exposure at a frequency of ion cyclotron resonance for K+ (16,5 Hz) exerts no noticeable effect on the duration of the pupal metamorphosis stage.
AI evidence extraction
Main findings
Exposure of Tenebrio molitor pupae to combined static (42 μT) and very weak alternating (250 nT) magnetic fields affected metamorphosis duration depending on the alternating-field frequency. At 4.4 Hz (ion cyclotron resonance frequency for glutaminic acid) metamorphosis was stimulated (shorter pupal stage), while at 32.2 Hz (for Ca2+) an inhibiting effect was observed; at 16.5 Hz (for K+) no noticeable effect was reported.
Outcomes measured
- Duration of metamorphosis (pupa to imago)
Limitations
- Sample size not reported in abstract
- Exposure duration not reported in abstract
- Outcome measurement methods/statistics not described in abstract
- Findings are frequency-specific and include null effects at some frequencies
View raw extracted JSON
{
"study_type": "animal",
"exposure": {
"band": "ELF",
"source": "other",
"frequency_mhz": null,
"sar_wkg": null,
"duration": null
},
"population": "Mealworm beetle (Tenebrio molitor) pupae",
"sample_size": null,
"outcomes": [
"Duration of metamorphosis (pupa to imago)"
],
"main_findings": "Exposure of Tenebrio molitor pupae to combined static (42 μT) and very weak alternating (250 nT) magnetic fields affected metamorphosis duration depending on the alternating-field frequency. At 4.4 Hz (ion cyclotron resonance frequency for glutaminic acid) metamorphosis was stimulated (shorter pupal stage), while at 32.2 Hz (for Ca2+) an inhibiting effect was observed; at 16.5 Hz (for K+) no noticeable effect was reported.",
"effect_direction": "mixed",
"limitations": [
"Sample size not reported in abstract",
"Exposure duration not reported in abstract",
"Outcome measurement methods/statistics not described in abstract",
"Findings are frequency-specific and include null effects at some frequencies"
],
"evidence_strength": "low",
"confidence": 0.74,
"peer_reviewed_likely": "yes",
"keywords": [
"Tenebrio molitor",
"mealworm beetle",
"pupae",
"metamorphosis",
"static magnetic field",
"alternating magnetic field",
"42 μT",
"250 nT",
"4.4 Hz",
"32.2 Hz",
"16.5 Hz",
"ion cyclotron resonance"
],
"suggested_hubs": [
{
"slug": "elf-magnetic-fields",
"weight": 0.9,
"reason": "Study involves very low-frequency alternating magnetic fields combined with a static magnetic field and reports biological effects dependent on frequency."
}
]
}AI can be wrong. Always verify against the paper.
Comments
Log in to comment.
No comments yet.
NNEMF synthesis
Synthesis pending.