EMF biological effects
Share

[The influence of alternating magnetic field on in vitro litholysis of uroliths in blemaren water solutions].

V M Popkov, D A Usanov, V G Rebrov, A D Usanov, D G Verkhov, V M Bulanov

PAPERpubmedUrologiia (Moscow, Russia : 1999)2016In vitro studyEffect: benefitEvidence: Low

Abstract

UNLABELLED: THE AIM OF THE RESEARCH: increase of efficiency of urolith in vitro solution using water Blemaren medication solutions after their exposure to 2 Hz alternating magnetic field. MATERIALS AND METHODS: water solution of Blemaren medication with pH=6,15 in concentrations corresponding to single portion of medication (1 tablet m=3,5282 g per 250 ml of water) and uroliths (oxalates, urates including uncommon xanthine calculi). Composition of calculi was determined by means of X-ray tests and IR spectroscopy. Photometry of Blemaren with saluted portion of calculi was conducted. RESULTS: it was established that in the Blemaren solutions which had been previously exposed to 2 Hz alternating magnetic filed during one hour the solution process is 1.92 - 2 times more effective than in common water solutions. Discussion - in control solutions pH values increased 5.65 - 6.8 times in the course of time, whereas in the Blemaren solutions exposed to alternating magnetic field pH values remained virtually unaltered during the whole experiment. CONCLUSION: there were detected significant differences in pH values of Blemaren solutions and its solvent properties between solutions which were exposed to alternating magnetic filed and those which were not.

AI evidence extraction

At a glance
Study type
In vitro study
Effect direction
benefit
Population
—
Sample size
—
Exposure
ELF alternating magnetic field · 0.000002 MHz · 1 hour
Evidence strength
Low
Confidence: 74% · Peer-reviewed: yes

Main findings

Blemaren water solutions previously exposed to a 2 Hz alternating magnetic field for one hour showed a 1.92–2× more effective dissolution process than non-exposed solutions. In control solutions pH increased over time, whereas in magnetic-field-exposed solutions pH remained virtually unchanged during the experiment.

Outcomes measured

  • In vitro litholysis (dissolution) efficiency of uroliths in Blemaren water solution
  • pH changes of Blemaren solutions over time
  • Solvent properties of Blemaren solutions

Limitations

  • In vitro study (no clinical outcomes reported)
  • No sample size reported in abstract
  • Exposure characterization limited to frequency and duration (field strength not reported)
View raw extracted JSON
{
  "study_type": "in_vitro",
  "exposure": {
    "band": "ELF",
    "source": "alternating magnetic field",
    "frequency_mhz": 0.000002,
    "sar_wkg": null,
    "duration": "1 hour"
  },
  "population": null,
  "sample_size": null,
  "outcomes": [
    "In vitro litholysis (dissolution) efficiency of uroliths in Blemaren water solution",
    "pH changes of Blemaren solutions over time",
    "Solvent properties of Blemaren solutions"
  ],
  "main_findings": "Blemaren water solutions previously exposed to a 2 Hz alternating magnetic field for one hour showed a 1.92–2× more effective dissolution process than non-exposed solutions. In control solutions pH increased over time, whereas in magnetic-field-exposed solutions pH remained virtually unchanged during the experiment.",
  "effect_direction": "benefit",
  "limitations": [
    "In vitro study (no clinical outcomes reported)",
    "No sample size reported in abstract",
    "Exposure characterization limited to frequency and duration (field strength not reported)"
  ],
  "evidence_strength": "low",
  "confidence": 0.74,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "alternating magnetic field",
    "2 Hz",
    "ELF",
    "in vitro",
    "litholysis",
    "uroliths",
    "oxalates",
    "urates",
    "xanthine calculi",
    "Blemaren",
    "pH"
  ],
  "suggested_hubs": [
    {
      "slug": "elF-health",
      "weight": 0.55,
      "reason": "Study involves exposure of solutions to a 2 Hz alternating magnetic field (ELF range) and reports changes in dissolution/pH outcomes."
    }
  ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 2898

[The influence of alternating magnetic field on in vitro litholysis of uroliths in blemaren water solutions]. · Non-native EMF