Share

Left versus bi-atrial intraoperative saline-irrigated radiofrequency modified maze procedure for atrial fibrillation.

Mustafa Guden, Belhhan Akpinar, Baris Caynak, Cavlan Turkoglu, Zeki Ozyedek, Ilhan Sanisoglu, Ertan Sagbas, Saide Aytekin, Seher Deniz Oztekin

PAPERpubmedCardiac electrophysiology review2003OtherEffect: unclearEvidence: Low

Abstract

BACKGROUND: This study was conducted to evaluate the effectiveness of the saline-irrigated radiofrequency modified maze operation for the treatment of chronic atrial fibrillation (AF) and compare the results of the left and bi-atrial procedures. MATERIAL AND METHOD: During a period of two years, 105 patients with chronic AF having concomitant cardiac surgery underwent the procedure. Patients underwent either a bi-atrial ( n = 48) or left atrial ( n = 57) maze procedure. The first twenty patients underwent a bi-atrial maze procedure regardless of the pathology. In the following patients we adopted the bi-atrial approach in patients with a history of atrial flutter and where the right atrium has to be opened. Otherwise the procedure is restricted to the left atrial side. Mean age was 52 +/- 11 years in bi-atrial group and 54 +/- 9 years in left atrial group. RESULTS: Three patients died early postoperatively (2.9%). There were 4 revisions for bleeding (3.8%). Two patients in bi-atrial group received a permanent pacemaker (4.1%). Patients in both groups were free of AF at the end of the procedure. (Bi-atrial group: sinus: 79.2%, pacemaker: 20.8%), (Left atrial group: sinus: 82.5%, pacemaker: 17.5%) ( p > 0.05). During the last follow-up, sinus rhythm was maintained in 79.6% of cases in bi-atrial group, while this rate was 75.6% in left atrial group ( p > 0.05). CONCLUSION: Saline irrigated radiofrequency modified maze procedure was performed safely and efficiently. Both the left and bi-atrial procedures were successful in terms of restoring sinus rhythm. Our current policy is to adopt the bi-atrial approach in patients with a history of atrial flutter and where the right atrium has to be opened. Otherwise the procedure is restricted to the left atrial side.

AI evidence extraction

At a glance
Study type
Other
Effect direction
unclear
Population
Patients with chronic atrial fibrillation undergoing concomitant cardiac surgery
Sample size
105
Exposure
RF
Evidence strength
Low
Confidence: 74% · Peer-reviewed: yes

Main findings

In 105 patients undergoing saline-irrigated radiofrequency modified maze during concomitant cardiac surgery, both bi-atrial (n=48) and left atrial (n=57) procedures resulted in patients being free of AF at the end of the procedure, with no significant between-group differences. At last follow-up, sinus rhythm was maintained in 79.6% (bi-atrial) vs 75.6% (left atrial) (p>0.05). Early postoperative mortality was 2.9%, bleeding revisions 3.8%, and 4.1% of bi-atrial patients received a permanent pacemaker.

Outcomes measured

  • Freedom from atrial fibrillation / restoration of sinus rhythm
  • Postoperative mortality
  • Revisions for bleeding
  • Permanent pacemaker implantation

Limitations

  • Non-randomized group assignment (first 20 patients received bi-atrial regardless of pathology
  • later selection based on clinical factors)
  • Follow-up duration not specified in abstract
  • Details of follow-up methods and AF ascertainment not provided
  • No radiofrequency exposure parameters (e.g.
  • frequency
  • power
  • lesion set specifics) reported
View raw extracted JSON
{
  "study_type": "other",
  "exposure": {
    "band": null,
    "source": "intraoperative saline-irrigated radiofrequency (surgical ablation)",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": null
  },
  "population": "Patients with chronic atrial fibrillation undergoing concomitant cardiac surgery",
  "sample_size": 105,
  "outcomes": [
    "Freedom from atrial fibrillation / restoration of sinus rhythm",
    "Postoperative mortality",
    "Revisions for bleeding",
    "Permanent pacemaker implantation"
  ],
  "main_findings": "In 105 patients undergoing saline-irrigated radiofrequency modified maze during concomitant cardiac surgery, both bi-atrial (n=48) and left atrial (n=57) procedures resulted in patients being free of AF at the end of the procedure, with no significant between-group differences. At last follow-up, sinus rhythm was maintained in 79.6% (bi-atrial) vs 75.6% (left atrial) (p>0.05). Early postoperative mortality was 2.9%, bleeding revisions 3.8%, and 4.1% of bi-atrial patients received a permanent pacemaker.",
  "effect_direction": "unclear",
  "limitations": [
    "Non-randomized group assignment (first 20 patients received bi-atrial regardless of pathology; later selection based on clinical factors)",
    "Follow-up duration not specified in abstract",
    "Details of follow-up methods and AF ascertainment not provided",
    "No radiofrequency exposure parameters (e.g., frequency, power, lesion set specifics) reported"
  ],
  "evidence_strength": "low",
  "confidence": 0.74,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "atrial fibrillation",
    "maze procedure",
    "radiofrequency ablation",
    "saline-irrigated",
    "bi-atrial",
    "left atrial",
    "cardiac surgery",
    "sinus rhythm"
  ],
  "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 3739

Left versus bi-atrial intraoperative saline-irrigated radiofrequency modified maze procedure for atrial fibrillation. · Non-native EMF