Share

Radiofrequency Pulmonary Vein Isolation in a Patient with Dextrocardia With Situs Inversus Totalis.

John Meulet, Geoffrey Trim, Ben Hunt, Kang-Teng Lim, Andrew James, Albert Henry, Wayne Pirihi, Paul Davies, Jason Brabant

PAPERpubmedHeart, lung & circulation2017Case reportEffect: unclearEvidence: Very low

Abstract

BACKGROUND: We present a case report of a 67-year-old male with dextrocardia situs inversus totalis and persistent atrial fibrillation who presented for radiofrequency pulmonary vein isolation. METHODS: Pulmonary vein isolation was performed using the St Jude Medical Ensite NavX 3D mapping system with AccuNav ICE guidance. RESULTS: All pulmonary veins were successfully isolated. The procedure time was 125 mins with a fluoroscopy time of 44.3 mins. The fluoro dose was 2095cGycm2. There were no procedural complications. CONCLUSIONS: Radiofrequency pulmonary vein isolation can be performed safely and successfully in patients with dextrocardia and situs inversus totalis.

AI evidence extraction

At a glance
Study type
Case report
Effect direction
unclear
Population
67-year-old male with dextrocardia with situs inversus totalis and persistent atrial fibrillation
Sample size
1
Exposure
radiofrequency pulmonary vein isolation (catheter ablation) · procedure time 125 mins (fluoroscopy time 44.3 mins)
Evidence strength
Very low
Confidence: 74% · Peer-reviewed: yes

Main findings

In this single patient, all pulmonary veins were successfully isolated using a 3D mapping system with intracardiac echocardiography guidance. Procedure time was 125 minutes, fluoroscopy time 44.3 minutes, fluoroscopy dose 2095 cGycm2, and no procedural complications were reported.

Outcomes measured

  • Procedural success (pulmonary vein isolation)
  • Procedure time
  • Fluoroscopy time
  • Fluoroscopy dose
  • Procedural complications

Limitations

  • Single-patient case report
  • No RF exposure parameters (e.g.
  • frequency
  • power
  • SAR) reported
  • No follow-up outcomes reported in the abstract
View raw extracted JSON
{
  "study_type": "case_report",
  "exposure": {
    "band": null,
    "source": "radiofrequency pulmonary vein isolation (catheter ablation)",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": "procedure time 125 mins (fluoroscopy time 44.3 mins)"
  },
  "population": "67-year-old male with dextrocardia with situs inversus totalis and persistent atrial fibrillation",
  "sample_size": 1,
  "outcomes": [
    "Procedural success (pulmonary vein isolation)",
    "Procedure time",
    "Fluoroscopy time",
    "Fluoroscopy dose",
    "Procedural complications"
  ],
  "main_findings": "In this single patient, all pulmonary veins were successfully isolated using a 3D mapping system with intracardiac echocardiography guidance. Procedure time was 125 minutes, fluoroscopy time 44.3 minutes, fluoroscopy dose 2095 cGycm2, and no procedural complications were reported.",
  "effect_direction": "unclear",
  "limitations": [
    "Single-patient case report",
    "No RF exposure parameters (e.g., frequency, power, SAR) reported",
    "No follow-up outcomes reported in the abstract"
  ],
  "evidence_strength": "very_low",
  "confidence": 0.74,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "radiofrequency",
    "pulmonary vein isolation",
    "catheter ablation",
    "dextrocardia",
    "situs inversus totalis",
    "atrial fibrillation",
    "fluoroscopy"
  ],
  "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 2873

Radiofrequency Pulmonary Vein Isolation in a Patient with Dextrocardia With Situs Inversus Totalis. · Non-native EMF