EMF biological effects
Share

Magnetic resonance imaging of hepatocellular carcinoma in Long-Evans cinnamon rats under a magnetic field of 7.05 T.

T Asanuma, Y Hirano, K Ohkura, Y Kon, S Shimokawa, N Kasai, M Kuwabara

PAPERpubmedThe Japanese journal of veterinary research1997Animal studyEffect: unclearEvidence: Insufficient

Abstract

Magnetic resonance (MR) images of livers in 3-, 12- and 29-month-old Long-Evans Cinnamon(LEC) rats (male) were taken under a magnetic field of 7.05 T. MR images of sagittal and transversal sections were obtained in 1-mm-thick slices by T1-weighted and two-dimensional Fourier transformation techniques. The data matrix size was 256 phase-encoded steps. Each image was obtained through four acquisitions. Three-month-old rats gave MR images with low signal intensity over the liver probably due to the shorting of its T1 and T2 relaxation times. However, 12-month-old rats gave hyperintense regions around hepatic veins in right hepatic lobe, which was assigned to hepatocellular carcinoma. In 29-month-old rats, MR images with hyperintensity throughout the hepatic lobe were observed. These MR images, therefore, suggested that hepatocellular carcinoma in LEC rats developed from the restricted regions surrounding hepatic veins. In the present study, T1-weighted MR imaging under a magnetic field of 7.05 T was shown to be applicable to the diagnosis of hepatic cancer in LEC rats.

AI evidence extraction

At a glance
Study type
Animal study
Effect direction
unclear
Population
Male Long-Evans Cinnamon (LEC) rats aged 3, 12, and 29 months
Sample size
—
Exposure
magnetic resonance imaging (MRI) static magnetic field
Evidence strength
Insufficient
Confidence: 74% · Peer-reviewed: yes

Main findings

T1-weighted MR images acquired under a 7.05 T magnetic field showed age-related liver signal patterns in LEC rats: low signal intensity at 3 months, hyperintense regions around hepatic veins at 12 months (assigned to hepatocellular carcinoma), and hyperintensity throughout the hepatic lobe at 29 months. The imaging findings suggested HCC developed from restricted regions surrounding hepatic veins and that 7.05 T T1-weighted MRI was applicable for diagnosing hepatic cancer in this rat model.

Outcomes measured

  • MRI liver signal intensity patterns on T1-weighted images
  • Detection/diagnosis of hepatocellular carcinoma (HCC) location and extent

Limitations

  • Sample size not reported in the abstract
  • No quantitative exposure metrics beyond magnetic field strength (e.g.
  • scan time
  • RF parameters
  • SAR)
  • Primarily an imaging/diagnostic study
  • does not assess health effects attributable to magnetic field exposure
View raw extracted JSON
{
  "study_type": "animal",
  "exposure": {
    "band": null,
    "source": "magnetic resonance imaging (MRI) static magnetic field",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": null
  },
  "population": "Male Long-Evans Cinnamon (LEC) rats aged 3, 12, and 29 months",
  "sample_size": null,
  "outcomes": [
    "MRI liver signal intensity patterns on T1-weighted images",
    "Detection/diagnosis of hepatocellular carcinoma (HCC) location and extent"
  ],
  "main_findings": "T1-weighted MR images acquired under a 7.05 T magnetic field showed age-related liver signal patterns in LEC rats: low signal intensity at 3 months, hyperintense regions around hepatic veins at 12 months (assigned to hepatocellular carcinoma), and hyperintensity throughout the hepatic lobe at 29 months. The imaging findings suggested HCC developed from restricted regions surrounding hepatic veins and that 7.05 T T1-weighted MRI was applicable for diagnosing hepatic cancer in this rat model.",
  "effect_direction": "unclear",
  "limitations": [
    "Sample size not reported in the abstract",
    "No quantitative exposure metrics beyond magnetic field strength (e.g., scan time, RF parameters, SAR)",
    "Primarily an imaging/diagnostic study; does not assess health effects attributable to magnetic field exposure"
  ],
  "evidence_strength": "insufficient",
  "confidence": 0.74,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "MRI",
    "7.05 T",
    "static magnetic field",
    "T1-weighted imaging",
    "Long-Evans Cinnamon rats",
    "hepatocellular carcinoma",
    "liver imaging"
  ],
  "suggested_hubs": [
    {
      "slug": "mri-static-fields",
      "weight": 0.9,
      "reason": "Study involves MRI performed under a 7.05 T magnetic field in an animal model."
    }
  ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 4151

Magnetic resonance imaging of hepatocellular carcinoma in Long-Evans cinnamon rats under a magnetic field of 7.05 T. · Non-native EMF