EMF biological effects
Share

Suppressive effect of electromagnetic field on analgesic activity of tramadol in rats.

P Bodera, W Stankiewicz, B Antkowiak, M Paluch, J Kieliszek, J Sobiech, R Zdanowski, A Wojdas, A K Siwicki, E Skopińska-Rózewska

PAPERpubmedPolish journal of veterinary sciences2012Animal studyEffect: mixedEvidence: Low

Abstract

The electromagnetic fields (EMFs) have been shown to alter animal and human behavior, such as directional orientation, learning, pain perception (nociception or analgesia) and anxiety-related behaviors. The aim of this study was to evaluate the influence of electromagnetic fields of high-frequency microwaves on pain perception and anti-nociceptive activity of tramadol (TRAM) - analgetic effective in the treatment of moderate to severe acute and chronic pain states. Electromagnetic fields exposures of a)1500 MHz frequency and b) modulated, 1800 MHz (which is identical to that generated by mobile phones) were applied. Paw withdrawal latency (PWL) to thermal stimulus was measured in vehicle or tramadol (TRAM) treated animals before and after 30, 60 and 90 minutes from injections. The differences in the level of pain (PWL) between control group and rats exposed to EMF alone in three measurements, were not observed. Tramadol alone significantly increased PWLs to thermal stimulus in comparison to vehicle results at 30 (p < 0.001) and 60 minutes (p < 0.05) after drug injection. EMF exposure of both frequencies transiently suppressed analgesic effect of tramadol, significantly reducing paw withdrawal latency in animals treated with this drug at 30 minutes from the drug injection.

AI evidence extraction

At a glance
Study type
Animal study
Effect direction
mixed
Population
rats
Sample size
—
Exposure
microwave 1000–3000 MHz
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes

Main findings

Exposure to high-frequency microwave EMF at 1500 MHz and modulated 1800 MHz did not change paw withdrawal latency compared with controls when EMF was applied alone. Tramadol increased paw withdrawal latency at 30 and 60 minutes after injection, but EMF exposure at both frequencies transiently suppressed tramadol’s analgesic effect, significantly reducing paw withdrawal latency at 30 minutes in tramadol-treated rats.

Outcomes measured

  • pain perception (paw withdrawal latency to thermal stimulus)
  • analgesic (anti-nociceptive) activity of tramadol

Limitations

  • Sample size not reported in abstract.
  • Exposure duration and intensity (e.g.
  • SAR) not reported in abstract.
  • Details of randomization/blinding and experimental controls not reported in abstract.
View raw extracted JSON
{
  "study_type": "animal",
  "exposure": {
    "band": "microwave",
    "source": "mobile phone",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": null
  },
  "population": "rats",
  "sample_size": null,
  "outcomes": [
    "pain perception (paw withdrawal latency to thermal stimulus)",
    "analgesic (anti-nociceptive) activity of tramadol"
  ],
  "main_findings": "Exposure to high-frequency microwave EMF at 1500 MHz and modulated 1800 MHz did not change paw withdrawal latency compared with controls when EMF was applied alone. Tramadol increased paw withdrawal latency at 30 and 60 minutes after injection, but EMF exposure at both frequencies transiently suppressed tramadol’s analgesic effect, significantly reducing paw withdrawal latency at 30 minutes in tramadol-treated rats.",
  "effect_direction": "mixed",
  "limitations": [
    "Sample size not reported in abstract.",
    "Exposure duration and intensity (e.g., SAR) not reported in abstract.",
    "Details of randomization/blinding and experimental controls not reported in abstract."
  ],
  "evidence_strength": "low",
  "confidence": 0.78,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "electromagnetic field",
    "microwave",
    "1500 MHz",
    "1800 MHz",
    "mobile phone",
    "tramadol",
    "analgesia",
    "nociception",
    "paw withdrawal latency",
    "rats"
  ],
  "suggested_hubs": [
    {
      "slug": "mobile-phones-rf",
      "weight": 0.9,
      "reason": "Includes modulated 1800 MHz exposure described as identical to that generated by mobile phones."
    }
  ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 4515

Suppressive effect of electromagnetic field on analgesic activity of tramadol in rats. · Non-native EMF