EMF biological effects
Share

Effects of extremely low frequency electromagnetic fields on morphine analgesia and tolerance in rats.

Ercan Ozdemir, Ayse Demirkazik, Sinan Gursoy, Ahmet S Taskıran, Olca Kilinc, Gokhan Arslan

PAPERpubmedGeneral physiology and biophysics2017Animal studyEffect: benefitEvidence: Low

Abstract

Several studies have demonstrated that the electromagnetic fields produce analgesic activity. The aim of this study was to investigate the effects of extremely low frequency (ELF) electromagnetic fields (EMF) on morphine analgesia and tolerance in rats. In the study, 78 adult male Wistar albino rats (approximately 240 ± 12 g) were used. The application of 50 Hz magnetic field, each day the same times for 30 minutes for 15 days, and a total of four times every 15 minute intervals. To constitute morphine tolerance, high dose of morphine (50 mg/kg) were administered for 3 days in rats and tolerance was evaluated on day 4. Prior to analgesia tests, the effective dose (5 mg/kg) of morphine was injected into rats. In the statistical analyzes of the data, analysis of variance (two-way ANOVA) was used and the multiple comparison determined by Tukey tests. The maximum analgesic effect of the 5 mT magnetic field was determined on 7 days. Administration of morphine (5 mg/kg) in rats exposed to a magnetic field, the analgesic effect was significantly higher compared to the morphine group (p < 0.05). Morphine tolerant animals exposed to a magnetic field, the analgesic effect was found significantly higher than morphine tolerant group rats (p < 0.05). Analgesia test data demonstrated that application of ELF-EMFs to rats increases the morphine analgesia and reduces morphine tolerance.

AI evidence extraction

At a glance
Study type
Animal study
Effect direction
benefit
Population
Adult male Wistar albino rats (~240 ± 12 g)
Sample size
78
Exposure
ELF other · 30 minutes/day for 15 days (50 Hz magnetic field; total of four times every 15-minute intervals each day)
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes

Main findings

Rats exposed to a 50 Hz magnetic field showed significantly higher morphine analgesic effect compared with morphine-only rats (p < 0.05). In morphine-tolerant rats, magnetic-field exposure was associated with significantly higher analgesic effect than in morphine-tolerant controls (p < 0.05), interpreted as reduced morphine tolerance.

Outcomes measured

  • Morphine analgesic effect
  • Morphine tolerance (analgesic response in morphine-tolerant animals)

Limitations

  • Exposure details are incomplete in the abstract (e.g.
  • how 5 mT relates to the 50 Hz exposure protocol and whether other field strengths were tested).
  • Analgesia/tolerance measurement methods are not described in the abstract.
  • Randomization
  • blinding
  • and control/sham exposure conditions are not described in the abstract.
  • Animal study
  • generalizability to humans is uncertain.
View raw extracted JSON
{
  "study_type": "animal",
  "exposure": {
    "band": "ELF",
    "source": "other",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": "30 minutes/day for 15 days (50 Hz magnetic field; total of four times every 15-minute intervals each day)"
  },
  "population": "Adult male Wistar albino rats (~240 ± 12 g)",
  "sample_size": 78,
  "outcomes": [
    "Morphine analgesic effect",
    "Morphine tolerance (analgesic response in morphine-tolerant animals)"
  ],
  "main_findings": "Rats exposed to a 50 Hz magnetic field showed significantly higher morphine analgesic effect compared with morphine-only rats (p < 0.05). In morphine-tolerant rats, magnetic-field exposure was associated with significantly higher analgesic effect than in morphine-tolerant controls (p < 0.05), interpreted as reduced morphine tolerance.",
  "effect_direction": "benefit",
  "limitations": [
    "Exposure details are incomplete in the abstract (e.g., how 5 mT relates to the 50 Hz exposure protocol and whether other field strengths were tested).",
    "Analgesia/tolerance measurement methods are not described in the abstract.",
    "Randomization, blinding, and control/sham exposure conditions are not described in the abstract.",
    "Animal study; generalizability to humans is uncertain."
  ],
  "evidence_strength": "low",
  "confidence": 0.78,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "extremely low frequency",
    "ELF",
    "electromagnetic fields",
    "magnetic field",
    "50 Hz",
    "5 mT",
    "morphine",
    "analgesia",
    "tolerance",
    "rats",
    "Wistar"
  ],
  "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 4908

Effects of extremely low frequency electromagnetic fields on morphine analgesia and tolerance in rats. · Non-native EMF