Share

Acute effects of low-frequency electromagnetic fields on leukocyte-endothelial interactions in vivo.

Akira Ushiyama, Chiyoji Ohkubo

PAPERpubmedIn vivo (Athens, Greece)2004Animal studyEffect: mixedEvidence: Low

Abstract

BACKGROUND: To clarify the effect of extremely low frequency electromagnetic field (ELF-EMF) on the microcirculatory system, acute effects on leukocyte-endothelium interactions resulting from ELF-EMF exposure were examined with conscious BALB/c mice by means of a dorsal skinfold chamber. MATERIALS AND METHODS: The fluorescent dye, rhodamine 6G, was injected into the caudal vein to visualize leukocytes in vivo and to analyze leukocyte-endothelium interactions. Mice were exposed in vivo to 50 Hz linear sinusoidal wave EMF at magnetic flux densities of 3, 10 or 30 mT, for 30 minutes. RESULTS: The mean velocity of free flowing leukocytes in the center stream of venules revealed no distinct changes following exposure. However, at a flux density of 30 mT, the number of adherent leukocytes, defined as the total number of rolling and endothelium-adhering leukocytes, increased significantly following ELF-EMF exposure (p<0.05); no significant differences in adherent cell numbers were found in the 3 mT and 10 mT exposure groups or sham controls comparing pre- and post-exposure periods. CONCLUSION: These results demonstrated that high magnetic flux densities of ELF-EMF had an effect on leukocyte-endothelium interactions and indicated that a threshold level for this phenomenon exists in the range of 10-30 mT under these experimental conditions.

AI evidence extraction

At a glance
Study type
Animal study
Effect direction
mixed
Population
Conscious BALB/c mice (dorsal skinfold chamber model)
Sample size
—
Exposure
ELF · 0.05 MHz · 30 minutes
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes

Main findings

Exposure to 50 Hz sinusoidal EMF at 30 mT for 30 minutes significantly increased the number of adherent leukocytes (rolling + endothelium-adhering) compared with pre-exposure (p<0.05). No distinct changes were observed in mean velocity of free-flowing leukocytes, and no significant differences in adherent leukocyte numbers were found at 3 mT or 10 mT or in sham controls.

Outcomes measured

  • Leukocyte velocity in venules (free-flowing leukocytes)
  • Number of adherent leukocytes (rolling + endothelium-adhering)
  • Leukocyte-endothelium interactions in vivo

Limitations

  • Sample size not reported in the abstract
  • Acute exposure only (30 minutes)
  • no longer-term outcomes reported
  • Animal model
  • generalizability to humans not addressed
  • Exposure source/setup details beyond waveform
  • frequency
  • and flux density not provided in the abstract
View raw extracted JSON
{
  "study_type": "animal",
  "exposure": {
    "band": "ELF",
    "source": null,
    "frequency_mhz": 0.05,
    "sar_wkg": null,
    "duration": "30 minutes"
  },
  "population": "Conscious BALB/c mice (dorsal skinfold chamber model)",
  "sample_size": null,
  "outcomes": [
    "Leukocyte velocity in venules (free-flowing leukocytes)",
    "Number of adherent leukocytes (rolling + endothelium-adhering)",
    "Leukocyte-endothelium interactions in vivo"
  ],
  "main_findings": "Exposure to 50 Hz sinusoidal EMF at 30 mT for 30 minutes significantly increased the number of adherent leukocytes (rolling + endothelium-adhering) compared with pre-exposure (p<0.05). No distinct changes were observed in mean velocity of free-flowing leukocytes, and no significant differences in adherent leukocyte numbers were found at 3 mT or 10 mT or in sham controls.",
  "effect_direction": "mixed",
  "limitations": [
    "Sample size not reported in the abstract",
    "Acute exposure only (30 minutes); no longer-term outcomes reported",
    "Animal model; generalizability to humans not addressed",
    "Exposure source/setup details beyond waveform, frequency, and flux density not provided in the abstract"
  ],
  "evidence_strength": "low",
  "confidence": 0.78,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "extremely low frequency",
    "ELF-EMF",
    "50 Hz",
    "magnetic flux density",
    "3 mT",
    "10 mT",
    "30 mT",
    "microcirculation",
    "leukocyte-endothelial interactions",
    "rolling",
    "adhesion",
    "dorsal skinfold chamber",
    "BALB/c mice"
  ],
  "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 5229

Acute effects of low-frequency electromagnetic fields on leukocyte-endothelial interactions in vivo. · Non-native EMF