Share

Acute effects of whole-body exposure to static magnetic fields and 50-Hz electromagnetic fields on muscle microcirculation in anesthetized mice.

S Xu, H Okano, C Ohkubo

PAPERpubmedBioelectrochemistry (Amsterdam, Netherlands)2001Animal studyEffect: benefitEvidence: Low

Abstract

Acute microhemodynamic effects of static and alternating magnetic fields at a threshold level were investigated on modulating the muscle capillary mirocirculation in pentobarbital-anesthetized mice. The skin in a tibialis anterior was circularly removed with 1.5 mm diameter for intravital-microscopic recording of the capillary blood velocity in the tibialis anterior muscle. Fluorescein isothiocyanate (FITC)-labeled dextran (MW 150 kDa) was used for an in vivo fluorescent plasma marker of the muscle capillaries. Following a bolus injection of FITC-dextran solution into the caudal vein, the peak blood velocity in the muscle capillaries was measured prior to, during, and following exposure to static magnetic fields (SMF) or 50-Hz electromagnetic fields (EMF) using a fluorescence epi-illumination system. The whole body of experimental animals, placed on the observing stage of a fluorescence microscope, was exposed to SMF (0.3, 1 and 10 mT) or 50-Hz EMF (0.3 and 1 mT) for 10 min using a specially devised electromagnet. For sham exposure, the electromagnet was not energized. During exposure and post-exposure to SMF of 10 mT, the peak blood velocity significantly increased as compared to sham exposure. After the withdrawal of SMF and 50-Hz EMF of 1 mT, significant similar effects on the blood velocity were present or enhanced. These findings suggest that field intensity of 1 mT might be considered as a threshold level for enhancing muscle microcirculation under pentobarbital-induced hypnosis.

AI evidence extraction

At a glance
Study type
Animal study
Effect direction
benefit
Population
Pentobarbital-anesthetized mice
Sample size
—
Exposure
ELF laboratory electromagnet (whole-body exposure) · 10 min
Evidence strength
Low
Confidence: 74% · Peer-reviewed: yes

Main findings

Whole-body exposure for 10 min to static magnetic fields (SMF) at 10 mT significantly increased peak blood velocity in tibialis anterior muscle capillaries compared with sham during exposure and post-exposure. After withdrawal of SMF and 50-Hz EMF at 1 mT, significant similar effects on blood velocity were present or enhanced; the authors suggest 1 mT as a threshold level for enhancing muscle microcirculation under pentobarbital-induced hypnosis.

Outcomes measured

  • Muscle capillary peak blood velocity (tibialis anterior microcirculation)

Limitations

  • Sample size not reported in abstract
  • Only acute exposure (10 min) assessed
  • Animal model under pentobarbital anesthesia
  • generalizability to awake animals or humans unclear
  • Outcome limited to microcirculatory blood velocity in one muscle

Suggested hubs

  • occupational-exposure (0.7)
    Uses 50-Hz fields at mT levels, relevant to power-frequency exposure contexts, though this is a laboratory animal study.
View raw extracted JSON
{
  "study_type": "animal",
  "exposure": {
    "band": "ELF",
    "source": "laboratory electromagnet (whole-body exposure)",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": "10 min"
  },
  "population": "Pentobarbital-anesthetized mice",
  "sample_size": null,
  "outcomes": [
    "Muscle capillary peak blood velocity (tibialis anterior microcirculation)"
  ],
  "main_findings": "Whole-body exposure for 10 min to static magnetic fields (SMF) at 10 mT significantly increased peak blood velocity in tibialis anterior muscle capillaries compared with sham during exposure and post-exposure. After withdrawal of SMF and 50-Hz EMF at 1 mT, significant similar effects on blood velocity were present or enhanced; the authors suggest 1 mT as a threshold level for enhancing muscle microcirculation under pentobarbital-induced hypnosis.",
  "effect_direction": "benefit",
  "limitations": [
    "Sample size not reported in abstract",
    "Only acute exposure (10 min) assessed",
    "Animal model under pentobarbital anesthesia; generalizability to awake animals or humans unclear",
    "Outcome limited to microcirculatory blood velocity in one muscle"
  ],
  "evidence_strength": "low",
  "confidence": 0.74,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "static magnetic field",
    "50-Hz electromagnetic field",
    "ELF",
    "mouse",
    "anesthetized",
    "microcirculation",
    "capillary blood velocity",
    "tibialis anterior",
    "intravital microscopy",
    "FITC-dextran",
    "whole-body exposure",
    "millitesla"
  ],
  "suggested_hubs": [
    {
      "slug": "occupational-exposure",
      "weight": 0.2,
      "reason": "Uses 50-Hz fields at mT levels, relevant to power-frequency exposure contexts, though this is a laboratory animal study."
    }
  ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 5325

Acute effects of whole-body exposure to static magnetic fields and 50-Hz electromagnetic fields on muscle microcirculation in anesthetized mice. · Non-native EMF