How much are anesthesiologists exposed to electromagnetic fields in operating rooms?

Jong Hwa Lee, Haeng Chul Lee, Hoon Do Kim, Ji Young Kim, Deok Won Kim, Yong Taek Nam, Ki Jun Kim

PAPERpubmedYonsei medical journal2003exposure assessmentEffect: unclearEvidence: Low

Abstract

Numerous electronic devices have been introduced into the operating room. Although little is known about the relationship between exposure to electromagnetic fields (EMF) and health hazards, some authors reported its association with cancer or other diseases. We measured the amount of EMF exposure that an anesthesiologist gets in the operating room. The density of the magnetic field was checked by an extremely low frequency (ELF) field strength measurement system in the 19 operating rooms of our hospital. We measured the magnetic field intensity at a distance of 30 cm, 50 cm, and at the place where the anesthesiologist usually stands from the center of the main monitor. The average exposure quantities of magnetic fields in 19 operating rooms were 2.22 +/- 1.13 mG at 30 cm, 1.29 +/- 0.84 mG at 50 cm and 1.00 +/- 0.78 mG at the anesthesiologist's standing points respectively. Because quantities over 2 or 3 mG were accepted to be high radiation levels of EMF by many reports describing the hazards of EMF, we set 2 mG to be the cutoff value. In some of the 19 operating rooms, the measured EMF density exceeded our cutoff value. Although the health hazards related to EMF exposure are still equivocal, anesthesiologists should consider making an effort to improve their environment and reduce their exposure to EMF.

AI evidence extraction

At a glance
Study type
exposure assessment
Effect direction
unclear
Population
Anesthesiologists in operating rooms (hospital setting)
Sample size
19
Exposure
ELF <1 MHz
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes

Main findings

Magnetic field density measured in 19 operating rooms averaged 2.22 +/- 1.13 mG at 30 cm from the main monitor center, 1.29 +/- 0.84 mG at 50 cm, and 1.00 +/- 0.78 mG at the anesthesiologist's standing point. Using 2 mG as a cutoff for high exposure, some operating rooms exceeded this level.

Outcomes measured

  • Magnetic field density/intensity (mG) at specified distances/locations in operating rooms

Limitations

  • Health outcomes were not measured (exposure assessment only).
  • Cutoff value (2 mG) was based on prior reports and not justified within the study.
  • Frequency characteristics beyond 'ELF' were not reported.
  • Single-hospital setting may limit generalizability.

Suggested hubs

  • occupational-exposure (0.7)
    Measures EMF exposure levels for anesthesiologists in operating rooms (workplace exposure assessment).
View raw extracted JSON
{
  "study_type": "exposure_assessment",
  "exposure": {
    "band": "ELF",
    "source": "occupational (operating room electronic devices/monitor)",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": null
  },
  "population": "Anesthesiologists in operating rooms (hospital setting)",
  "sample_size": 19,
  "outcomes": [
    "Magnetic field density/intensity (mG) at specified distances/locations in operating rooms"
  ],
  "main_findings": "Magnetic field density measured in 19 operating rooms averaged 2.22 +/- 1.13 mG at 30 cm from the main monitor center, 1.29 +/- 0.84 mG at 50 cm, and 1.00 +/- 0.78 mG at the anesthesiologist's standing point. Using 2 mG as a cutoff for high exposure, some operating rooms exceeded this level.",
  "effect_direction": "unclear",
  "limitations": [
    "Health outcomes were not measured (exposure assessment only).",
    "Cutoff value (2 mG) was based on prior reports and not justified within the study.",
    "Frequency characteristics beyond 'ELF' were not reported.",
    "Single-hospital setting may limit generalizability."
  ],
  "evidence_strength": "low",
  "confidence": 0.78,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "electromagnetic fields",
    "ELF",
    "magnetic field density",
    "operating room",
    "anesthesiologist",
    "occupational exposure",
    "monitor"
  ],
  "suggested_hubs": [
    {
      "slug": "occupational-exposure",
      "weight": 0.9,
      "reason": "Measures EMF exposure levels for anesthesiologists in operating rooms (workplace exposure assessment)."
    }
  ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 5283

How much are anesthesiologists exposed to electromagnetic fields in operating rooms? · Non-native EMF