EMF biological effects
Share

Evaluation of aperture efficiency of a radiofrequency electric field strength meter antenna.

R N Sachdev, G Swarup, K K Rajan, L Joseph

PAPERpubmedHealth physics1997exposure assessmentEffect: unclearEvidence: Insufficient

Abstract

With present-day rapid increases in the applications of radiofrequency microwave radiation in research, medicine, defense, communications, and industry, it has become necessary to have simple inexpensive portable radiofrequency microwave field strength meters for health and safety surveys around operating equipment. This paper presents the results of a study conducted at Trombay calibrating grid to evaluate the receiving aperture efficiency of the 1-m long antenna of a simple narrow band electric field strength meter, with frequency response centered around 27.12 MHz. An aperture efficiency of 0.47 with a coefficient of variation of +/-3.46% is considered adequate for field use.

AI evidence extraction

At a glance
Study type
exposure assessment
Effect direction
unclear
Population
—
Sample size
—
Exposure
RF field strength meter antenna (measurement device) · 27.12 MHz
Evidence strength
Insufficient
Confidence: 78% · Peer-reviewed: yes

Main findings

A calibration study evaluated the receiving aperture efficiency of a 1-m antenna on a narrow-band electric field strength meter centered at 27.12 MHz. The reported aperture efficiency was 0.47 with a coefficient of variation of +/-3.46%, considered adequate for field use.

Outcomes measured

  • Aperture efficiency of a 1-m antenna for a narrow-band electric field strength meter
  • Coefficient of variation of aperture efficiency
View raw extracted JSON
{
  "study_type": "exposure_assessment",
  "exposure": {
    "band": "RF",
    "source": "field strength meter antenna (measurement device)",
    "frequency_mhz": 27.12,
    "sar_wkg": null,
    "duration": null
  },
  "population": null,
  "sample_size": null,
  "outcomes": [
    "Aperture efficiency of a 1-m antenna for a narrow-band electric field strength meter",
    "Coefficient of variation of aperture efficiency"
  ],
  "main_findings": "A calibration study evaluated the receiving aperture efficiency of a 1-m antenna on a narrow-band electric field strength meter centered at 27.12 MHz. The reported aperture efficiency was 0.47 with a coefficient of variation of +/-3.46%, considered adequate for field use.",
  "effect_direction": "unclear",
  "limitations": [],
  "evidence_strength": "insufficient",
  "confidence": 0.78,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "radiofrequency",
    "microwave",
    "field strength meter",
    "antenna",
    "aperture efficiency",
    "calibration",
    "27.12 MHz",
    "health and safety surveys"
  ],
  "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 6339