Share

[Effects of microwave radiation on thymocytes in mice at different power densities].

Xia Sun, Wen-hui Zhang, Yu-jie Niu, Ming Zeng, Yu-chun Hou, Xiu-rong Wang

PAPERpubmedZhonghua lao dong wei sheng zhi ye bing za zhi = Zhonghua laodong weisheng zhiyebing zazhi = Chinese journal of industrial hygiene and occupational diseases2004Animal studyEffect: harmEvidence: Low

Abstract

OBJECTIVE: To investigate the effects of microwave radiation on thymocytes in mice at different power densities. METHODS: The experimental animals were whole-body exposed to microwave radiation with frequency of 2,450 MHz, power density of 1, 5, 15 mW/cm(2) respectively 1 h everyday for 30 days. Then the thymus were taken out after the mice were decapitated. Thymus index, morphological characteristics of thymus were examined. The changes of thymus T-cell subgroups, cell cycle progression in thymocytes and cellular apoptosis were detected with flow cytometry (FCM). RESULTS: The body weights of animals in 5, 15 mW/cm(2) irradiation groups [(28.10 +/- 1.46), (27.50 +/- 2.52) g] were lower than that of the control [(31.95 +/- 2.51) g] (P < 0.05). Pathological observation showed dark red piece of nucleus, some nuclei inclined to one side, slight increase in hassall body. The expressions of CD8 in 5, 15 mW/cm(2) irradiation groups (29.14% +/- 1.68%, 29.18% +/- 0.81%) were higher than that in control group (26.95% +/- 1.27%) (P < 0.05). The percentages of G(2) + M phase thymocytes in both radiation groups (12.24% +/- 1.82%, 11.19% +/- 1.36%) were lower than that in control group (14.58% +/- 0.64%) (P < 0.01). Thymocytic apoptosis rates in the three experimental groups (7.18% +/- 0.99%, 10.06% +/- 1.58%, 9.45% +/- 0.92%) were higher than that in control (4.25% +/- 1.63%) (P < 0.01), but the evident difference between 5 mW/cm(2) and 15 mW/cm(2) was not found (P > 0.05). CONCLUSION: Sub-chronic microwave exposure (2 450 MHz, 5, 15 mW/cm(2)) could induce thymocyte apoptosis, cause pathological changes in thymus, and affect cell cycle progression, thus may inhibit the immune function of the animal.

AI evidence extraction

At a glance
Study type
Animal study
Effect direction
harm
Population
Mice (experimental animals)
Sample size
—
Exposure
microwave · 2450 MHz · 1 h/day for 30 days (whole-body exposure); power density 1, 5, 15 mW/cm^2
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes

Main findings

Compared with controls, mice exposed to 2,450 MHz microwaves showed lower body weight at 5 and 15 mW/cm^2, pathological changes in thymus, higher CD8 expression at 5 and 15 mW/cm^2, lower G2+M phase thymocytes at 5 and 15 mW/cm^2, and higher thymocyte apoptosis rates at 1, 5, and 15 mW/cm^2. No significant difference in apoptosis rate was observed between 5 and 15 mW/cm^2.

Outcomes measured

  • Body weight
  • Thymus index
  • Thymus morphology/pathology
  • T-cell subgroups (CD8 expression)
  • Cell cycle progression in thymocytes (G2+M phase %)
  • Thymocyte apoptosis rate

Limitations

  • Sample size not reported in abstract
  • SAR not reported
  • exposure characterized by power density only
  • Details of randomization/blinding not described in abstract
  • Some outcomes reported only for 5 and 15 mW/cm^2 (not clearly for 1 mW/cm^2)
View raw extracted JSON
{
  "study_type": "animal",
  "exposure": {
    "band": "microwave",
    "source": null,
    "frequency_mhz": 2450,
    "sar_wkg": null,
    "duration": "1 h/day for 30 days (whole-body exposure); power density 1, 5, 15 mW/cm^2"
  },
  "population": "Mice (experimental animals)",
  "sample_size": null,
  "outcomes": [
    "Body weight",
    "Thymus index",
    "Thymus morphology/pathology",
    "T-cell subgroups (CD8 expression)",
    "Cell cycle progression in thymocytes (G2+M phase %)",
    "Thymocyte apoptosis rate"
  ],
  "main_findings": "Compared with controls, mice exposed to 2,450 MHz microwaves showed lower body weight at 5 and 15 mW/cm^2, pathological changes in thymus, higher CD8 expression at 5 and 15 mW/cm^2, lower G2+M phase thymocytes at 5 and 15 mW/cm^2, and higher thymocyte apoptosis rates at 1, 5, and 15 mW/cm^2. No significant difference in apoptosis rate was observed between 5 and 15 mW/cm^2.",
  "effect_direction": "harm",
  "limitations": [
    "Sample size not reported in abstract",
    "SAR not reported; exposure characterized by power density only",
    "Details of randomization/blinding not described in abstract",
    "Some outcomes reported only for 5 and 15 mW/cm^2 (not clearly for 1 mW/cm^2)"
  ],
  "evidence_strength": "low",
  "confidence": 0.78,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "microwave radiation",
    "2450 MHz",
    "power density",
    "whole-body exposure",
    "mice",
    "thymocytes",
    "thymus",
    "apoptosis",
    "cell cycle",
    "CD8",
    "immune function"
  ],
  "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 6414

[Effects of microwave radiation on thymocytes in mice at different power densities]. · Non-native EMF