Geomagnetic storm under laboratory conditions: randomized experiment
Abstract
Geomagnetic storm under laboratory conditions: randomized experiment Gurfinkel YI, Vasin AL, Pishchalnikov RY, Sarimov RM, Sasonko ML, Matveeva TA. Geomagnetic storm under laboratory conditions: randomized experiment. Int J Biometeorol. 2017 Oct 13. doi: 10.1007/s00484-017-1460- 8. Abstract The influence of the previously recorded geomagnetic storm (GS) on human cardiovascular system and microcirculation has been studied under laboratory conditions. Healthy volunteers in lying position were exposed under two artificially created conditions: quiet (Q) and storm (S). The Q regime playbacks a noise-free magnetic field (MF) which is closed to the natural geomagnetic conditions on Moscow's latitude. The S regime playbacks the initially recorded 6-h geomagnetic storm which is repeated four times sequentially. The cardiovascular response to the GS impact was assessed by measuring capillary blood velocity (CBV) and blood pressure (BP) and by the analysis of the 24-h ECG recording. A storm-to-quiet ratio for the cardio intervals (CI) and the heart rate variability (HRV) was introduced in order to reveal the average over group significant differences of HRV. An individual sensitivity to the GS was estimated using the autocorrelation function analysis of the high-frequency (HF) part of the CI spectrum. The autocorrelation analysis allowed for detection a group of subjects of study which autocorrelation functions (ACF) react differently in the Q and S regimes of exposure. ncbi.nlm.nih.gov
AI evidence extraction
Main findings
In a randomized laboratory experiment, healthy volunteers were exposed to quiet versus storm magnetic-field playback conditions, and cardiovascular/microcirculation responses were assessed using CBV, BP, and 24-h ECG-derived measures (CI/HRV). Autocorrelation analysis of the HF part of the CI spectrum was used to identify a subgroup whose ACF reacted differently between quiet and storm exposure regimes.
Outcomes measured
- capillary blood velocity (CBV)
- blood pressure (BP)
- 24-h ECG
- cardio intervals (CI)
- heart rate variability (HRV)
- high-frequency (HF) part of CI spectrum autocorrelation function (ACF)
Limitations
- Sample size not reported in the abstract
- No quantitative results or effect sizes reported in the abstract
- Exposure metrics (field strength
- detailed frequency content) not reported in the abstract
Suggested hubs
- who-icnirp (0.7)Study concerns magnetic-field exposure and physiological outcomes, potentially relevant to EMF health guidance context.
View raw extracted JSON
{
"study_type": "randomized_trial",
"exposure": {
"band": "ELF",
"source": "geomagnetic storm simulation (artificially created magnetic field playback)",
"frequency_mhz": null,
"sar_wkg": null,
"duration": "6-h geomagnetic storm playback repeated four times sequentially"
},
"population": "Healthy volunteers",
"sample_size": null,
"outcomes": [
"capillary blood velocity (CBV)",
"blood pressure (BP)",
"24-h ECG",
"cardio intervals (CI)",
"heart rate variability (HRV)",
"high-frequency (HF) part of CI spectrum autocorrelation function (ACF)"
],
"main_findings": "In a randomized laboratory experiment, healthy volunteers were exposed to quiet versus storm magnetic-field playback conditions, and cardiovascular/microcirculation responses were assessed using CBV, BP, and 24-h ECG-derived measures (CI/HRV). Autocorrelation analysis of the HF part of the CI spectrum was used to identify a subgroup whose ACF reacted differently between quiet and storm exposure regimes.",
"effect_direction": "unclear",
"limitations": [
"Sample size not reported in the abstract",
"No quantitative results or effect sizes reported in the abstract",
"Exposure metrics (field strength, detailed frequency content) not reported in the abstract"
],
"evidence_strength": "insufficient",
"confidence": 0.66,
"peer_reviewed_likely": "yes",
"keywords": [
"geomagnetic storm",
"magnetic field",
"laboratory exposure",
"randomized experiment",
"cardiovascular",
"microcirculation",
"capillary blood velocity",
"blood pressure",
"ECG",
"heart rate variability",
"autocorrelation"
],
"suggested_hubs": [
{
"slug": "who-icnirp",
"weight": 0.2,
"reason": "Study concerns magnetic-field exposure and physiological outcomes, potentially relevant to EMF health guidance context."
}
]
}AI can be wrong. Always verify against the paper.
Comments
Log in to comment.
No comments yet.
NNEMF synthesis
Synthesis pending.